{"title":"EX600","description":null,"products":[{"product_id":"ex600-wsv1","title":"EX600-W, Modular Type, Wireless System, Remote Unit | EX600-WSV1","description":"\u003cp\u003e\u003cstrong\u003eREMOTE MODULE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWireless serial transmission system for input\/output\nCompatible protocols: EtherNet\/IPTM, PROFINET, CC-Link, EtherCAT, IO-Link\nUp to 127 remotes per base\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nUp to IP67 enclosure compliant.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWireless serial transmission system for input\/output\u003c\/li\u003e\n\u003cli\u003eUp to 127 inputs \/ 127 outputs\u003c\/li\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC, S0700, SV\u003c\/li\u003e\n\u003cli\u003eCommunication distance: up to 10 m\u003c\/li\u003e\n\u003cli\u003eIP67 enclosure compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-WSV1\u003c\/li\u003e\n\u003cli\u003eItem number: 01703727\u003c\/li\u003e\n\u003cli\u003eLead time: 115 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EXW1-EX600-W-F_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-WSV1\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642541670790,"sku":"EX600-WSV1","price":867.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/1001GFl.jpg?v=1792335011"},{"product_id":"ex600-sen7","title":"EX600, SI Unit | EX600-SEN7","description":"\u003cp\u003e\u003cstrong\u003eSERIAL INTERFACE UNIT\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK.\u003c\/li\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC, S0700, SV.\u003c\/li\u003e\n\u003cli\u003eUp to 9 input \/ output\/ IO-Link units.\u003c\/li\u003e\n\u003cli\u003eUp to 1280 inputs \/ 1280 outputs.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-SEN7\u003c\/li\u003e\n\u003cli\u003eItem number: 02535238\u003c\/li\u003e\n\u003cli\u003eType: S (Wired)\u003c\/li\u003e\n\u003cli\u003eProtocol: EN (EtherNet\/IP™)\u003c\/li\u003e\n\u003cli\u003eOutput type: 7 [PNP, -COM, (IO-link)]\u003c\/li\u003e\n\u003cli\u003eSuffix: None\u003c\/li\u003e\n\u003cli\u003eLead time: 120 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-SEN7\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-smjx_cc-link_en-c.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-secx-ethercat_en-a.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sdnx_devicenet_en-f.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn1-2_profinet_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sen1-2_ethernetip_en-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 5\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600-sen1-2_ethernetip_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 6\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sprxa-profibus-dp_en-e.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 7\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sen3-4_ethernetip-dualport_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 8\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600_sen3-4_ethernetip-dualport_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 9\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn3-4_profinet_en-a.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 10\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600_ethernetip_io-link_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 11\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-smj_tf2z145en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-secx_tf2z166en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sdnxa_tf2z158en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-spn1-2_tf2z175en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen1-2_tf2z159en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 5\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sprxa_tf2z157en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 6\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-spn3-4_tf2z192en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 7\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen3-4_tf2z179en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 8\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen3-x80_tf2z189en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 9\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642541703558,"sku":"EX600-SEN7","price":831.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5062l.jpg?v=1792335011"},{"product_id":"ex600-sec3","title":"EX600, SI Unit | EX600-SEC3","description":"\u003cp\u003e\u003cstrong\u003eSERIAL INTERFACE UNIT\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK.\u003c\/li\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC, S0700, SV.\u003c\/li\u003e\n\u003cli\u003eUp to 9 input \/ output\/ IO-Link units.\u003c\/li\u003e\n\u003cli\u003eUp to 1280 inputs \/ 1280 outputs.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-SEC3\u003c\/li\u003e\n\u003cli\u003eItem number: 02554570\u003c\/li\u003e\n\u003cli\u003eType: S (Wired)\u003c\/li\u003e\n\u003cli\u003eProtocol: EC (EtherCAT®)\u003c\/li\u003e\n\u003cli\u003eOutput type: 3 [PNP, -COM; EtherNet\/IP™, (2 Ports); PROFINET, EtherCAT® (IO-link)]\u003c\/li\u003e\n\u003cli\u003eSuffix: None\u003c\/li\u003e\n\u003cli\u003eLead time: 19 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-SEC3\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-smjx_cc-link_en-c.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-secx-ethercat_en-a.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sdnx_devicenet_en-f.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn1-2_profinet_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sen1-2_ethernetip_en-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 5\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600-sen1-2_ethernetip_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 6\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sprxa-profibus-dp_en-e.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 7\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sen3-4_ethernetip-dualport_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 8\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600_sen3-4_ethernetip-dualport_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 9\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn3-4_profinet_en-a.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 10\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600_ethernetip_io-link_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 11\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-smj_tf2z145en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-secx_tf2z166en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sdnxa_tf2z158en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-spn1-2_tf2z175en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen1-2_tf2z159en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 5\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sprxa_tf2z157en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 6\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-spn3-4_tf2z192en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 7\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen3-4_tf2z179en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 8\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen3-x80_tf2z189en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 9\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642541736326,"sku":"EX600-SEC3","price":649.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5062l_e177cd6f-df0d-4698-bde2-f8e6a7ff028c.jpg?v=1792335012"},{"product_id":"ex600-dxpd","title":"EX600, Digital Input Unit | EX600-DXPD","description":"\u003cp\u003e\u003cstrong\u003eEX600 Digital Input Unit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link master units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUp to 16 inputs.\u003c\/li\u003e\n\u003cli\u003eInput type: PNP, NPN.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-DXPD\u003c\/li\u003e\n\u003cli\u003eItem number: 00501097\u003c\/li\u003e\n\u003cli\u003eInput Polarity: P (PNP)\u003c\/li\u003e\n\u003cli\u003eConnector, Input Points: D [8xM12(5 Pins), 16 Channels]\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-DXPD\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-dxx_digital-units_en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-dx_tfn26en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1y087en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/doc_ex600-x_tfm0014-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 3\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642573947270,"sku":"EX600-DXPD","price":326.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5057l.jpg?v=1792335605"},{"product_id":"ex600-dypb","title":"EX600, Digital Output Unit | EX600-DYPB","description":"\u003cp\u003e\u003cstrong\u003eEX600 Digital Output Unit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link master units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUp to 16 outputs.\u003c\/li\u003e\n\u003cli\u003eOutput style: PNP, NPN.\u003c\/li\u003e\n\u003cli\u003eUp to IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-DYPB\u003c\/li\u003e\n\u003cli\u003eItem number: 00501098\u003c\/li\u003e\n\u003cli\u003eOutput type: P (PNP)\u003c\/li\u003e\n\u003cli\u003eConnector and Number of Points: B [4xM12(5 Pins), 8 Channels]\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-DYPB\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-dxx_digital-units_en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-dx_tfn26en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1y087en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/doc_ex600-x_tfm0014-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 3\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642573980038,"sku":"EX600-DYPB","price":257.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5061l.jpg?v=1792335607"},{"product_id":"ex600-dxpc","title":"EX600, Digital Input Unit | EX600-DXPC","description":"\u003cp\u003e\u003cstrong\u003eEX600 Digital Input Unit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link master units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUp to 16 inputs.\u003c\/li\u003e\n\u003cli\u003eInput type: PNP, NPN.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-DXPC\u003c\/li\u003e\n\u003cli\u003eItem number: 00504525\u003c\/li\u003e\n\u003cli\u003eInput Polarity: P (PNP)\u003c\/li\u003e\n\u003cli\u003eConnector, Input Points: C [8xM8 (3 Pins), 8 Channels]\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-DXPC\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-dxx_digital-units_en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-dx_tfn26en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1y087en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/doc_ex600-x_tfm0014-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 3\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642574012806,"sku":"EX600-DXPC","price":231.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5057l_36b8a697-98ab-4caf-819b-d4faf4479d65.jpg?v=1792335607"},{"product_id":"ex600-axa","title":"EX600, Analogue Input Unit | EX600-AXA","description":"\u003cp\u003e\u003cstrong\u003eEX600 Analog I\/O Unit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eDecentralised \u0026amp; wireless serial transmission system for input\/output\nCompatible protocols: EtherNet\/IPTM, PROFINET\n127 remote per base\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: new SY, VQC, S0700, SV\nIP67 enclosure compliant.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 input channels.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-AXA\u003c\/li\u003e\n\u003cli\u003eItem number: 00504531\u003c\/li\u003e\n\u003cli\u003eConnector and Input Channel: A [2xM12(5P ins), 2 Channel]\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-AXA\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-axx_analogue-units_en-c.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-ax_tfn27en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1y087en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/doc_ex600-x_tfm0014-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 3\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642574045574,"sku":"EX600-AXA","price":343.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5056l.jpg?v=1792335610"},{"product_id":"ex600-dxpb","title":"EX600, Digital Input Unit | EX600-DXPB","description":"\u003cp\u003e\u003cstrong\u003eSERIAL INTERFACE UNIT\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link master units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUp to 16 inputs.\u003c\/li\u003e\n\u003cli\u003eInput type: PNP, NPN.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-DXPB\u003c\/li\u003e\n\u003cli\u003eItem number: 00504940\u003c\/li\u003e\n\u003cli\u003eInput Polarity: P (PNP)\u003c\/li\u003e\n\u003cli\u003eConnector, Input Points: B [4xM12(5 Pins), 8 Channels]\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-DXPB\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-dxx_digital-units_en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-dx_tfn26en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1y087en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/doc_ex600-x_tfm0014-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 3\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642574078342,"sku":"EX600-DXPB","price":231.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5057l_e7cbfa9a-6852-4d48-9fa1-b5b99a4f7e89.jpg?v=1792335609"},{"product_id":"ex600-spr1a","title":"EX600, SI Unit | EX600-SPR1A","description":"\u003cp\u003e\u003cstrong\u003eEX600 SI Unit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link master units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocols: EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK.\u003c\/li\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC, S0700, SV.\u003c\/li\u003e\n\u003cli\u003eUp to 9 input \/ output\/ IO-Link master units.\u003c\/li\u003e\n\u003cli\u003eUp to 1280 inputs \/ 1280 outputs.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-SPR1A\u003c\/li\u003e\n\u003cli\u003eItem number: 00725002\u003c\/li\u003e\n\u003cli\u003eType: S (Wired)\u003c\/li\u003e\n\u003cli\u003eProtocol: PR (PROFIBUS DP®)\u003c\/li\u003e\n\u003cli\u003eOutput type: 1 [PNP (-COM)]\u003c\/li\u003e\n\u003cli\u003eSuffix: A (For PROFIBUS DP or DeviceNet)\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-SPR1A\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600_ethernetip_io-link_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-smjx_cc-link_en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-secx-ethercat_en-a.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sdnx_devicenet_en-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600-sdnx_devicenet_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 5\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn1-2_profinet_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 6\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn3-4_profinet_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 7\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sen1-2_ethernetip_en-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 8\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600-sen1-2_ethernetip_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 9\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sprxa-profibus-dp_en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 10\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600-sprxa-profibus-dp_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 11\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sen3-4_ethernetip-dualport_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 12\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600_sen3-4_ethernetip-dualport_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 13\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen3-x80_tf2z189en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-smjx_tfl27en-a.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-secx_tfo35en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-sdnxa_tfn24en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-spnx_tfr01en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 5\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-senx_tfn25en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 6\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-sprxa_tfn23en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 7\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen_tf2z192en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 8\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642577322374,"sku":"EX600-SPR1A","price":533.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5062l_2f890779-007d-4e1a-8855-7b13fccbca7a.jpg?v=1792335662"},{"product_id":"ex600-amb","title":"EX600, Analogue Input\/Output Unit | EX600-AMB","description":"\u003cp\u003e\u003cstrong\u003eEX600 Analog I\/O Unit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eDecentralised \u0026amp; wireless serial transmission system for input\/output\nCompatible protocols: EtherNet\/IPTM, PROFINET\n127 remote per base\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: new SY, VQC, S0700, SV\nIP67 enclosure compliant.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2\/2 input\/output channels.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-AMB\u003c\/li\u003e\n\u003cli\u003eItem number: 00753413\u003c\/li\u003e\n\u003cli\u003eNumber of input\/output channels and connector: B [4xM12(5 Pins), 4 Channels]\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-AMB\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-axx_analogue-units_en-c.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-ax_tfn27en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1y087en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/doc_ex600-x_tfm0014-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 3\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642578338182,"sku":"EX600-AMB","price":482.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5061l_f386a2c8-b601-44ad-b4ea-2d2e1f645775.jpg?v=1792335667"},{"product_id":"ex600-aya","title":"EX600, Analogue Output Unit | EX600-AYA","description":"\u003cp\u003e\u003cstrong\u003eEX600 Analog I\/O Unit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link master units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 output channels.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-AYA\u003c\/li\u003e\n\u003cli\u003eItem number: 00753414\u003c\/li\u003e\n\u003cli\u003eConnector and Output Channel: A [2xM12(5P ins), 2 Channel]\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-AYA\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-axx_analogue-units_en-c.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-ax_tfn27en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1y087en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/doc_ex600-x_tfm0014-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 3\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642578436486,"sku":"EX600-AYA","price":361.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5056l_c68db75c-ac4d-428d-a592-c9ea1ebdad39.jpg?v=1792335668"},{"product_id":"ex600-dmpf","title":"EX600, Digital Input\/Output Unit | EX600-DMPF","description":"\u003cp\u003e\u003cstrong\u003eEX600 Digital I\/O Unit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link master units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUp to 8 inputs \/ 8 outputs.\u003c\/li\u003e\n\u003cli\u003eOutput style: PNP, NPN.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP40.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-DMPF\u003c\/li\u003e\n\u003cli\u003eItem number: 00753416\u003c\/li\u003e\n\u003cli\u003eInput Polarity: P (PNP)\u003c\/li\u003e\n\u003cli\u003eNumber of inputs\/outputs and connector: F [Spring type terminal block(32Pin), 8\/8 Channels]\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-DMPF\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-dxx_digital-units_en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/imm_ex600-dx_tfn26en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1y087en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/doc_ex600-x_tfm0014-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 3\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642579124614,"sku":"EX600-DMPF","price":277.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5060Cl.jpg?v=1792335670"},{"product_id":"ex600-lab1","title":"EX600, IO-Link Master Unit | EX600-LAB1","description":"\u003cp\u003e\u003cstrong\u003eIO-LINK MASTER UNIT\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe product EX600-SEC1\/SEC2 is being discontinued\nThe product EX600-SEN1\/SEN2 is being discontinued and will be replaced by EX600-SEN3\/SEN4 (https:\/\/www.smc.eu\/en-eu\/products\/~72940~cfg) series. Update details here (https:\/\/www.smc.eu\/en-eu\/new-products\/enhanced-products\/ex600~72940~enhanced-products).\nCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC.\u003c\/li\u003e\n\u003cli\u003ePort class A device: for input and input\/output devices.\u003c\/li\u003e\n\u003cli\u003ePort class B device: for output devices setting tool for data setting and monitoring.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-LAB1\u003c\/li\u003e\n\u003cli\u003eItem number: 02061664\u003c\/li\u003e\n\u003cli\u003eNumber of Ports: B (4 Ports\u003c\/li\u003e\n\u003cli\u003eM12 Connector, 5 Pins, 4 pcs.):\u003c\/li\u003e\n\u003cli\u003ePort Specification: A (Port Class A)\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-LAB1\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-lxb1_io-link_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-lxb1_tf2z188en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1y087en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 2\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642585612678,"sku":"EX600-LAB1","price":320.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5059Al.jpg?v=1792335840"},{"product_id":"ex600-lbb1","title":"EX600, IO-Link Master Unit | EX600-LBB1","description":"\u003cp\u003e\u003cstrong\u003eIO-LINK MASTER UNIT\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe product EX600-SEC1\/SEC2 is being discontinued\nThe product EX600-SEN1\/SEN2 is being discontinued and will be replaced by EX600-SEN3\/SEN4 (https:\/\/www.smc.eu\/en-eu\/products\/~72940~cfg) series. Update details here (https:\/\/www.smc.eu\/en-eu\/new-products\/enhanced-products\/ex600~72940~enhanced-products).\nCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC.\u003c\/li\u003e\n\u003cli\u003ePort class A device: for input and input\/output devices.\u003c\/li\u003e\n\u003cli\u003ePort class B device: for output devices setting tool for data setting and monitoring.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-LBB1\u003c\/li\u003e\n\u003cli\u003eItem number: 02061668\u003c\/li\u003e\n\u003cli\u003eNumber of Ports: B (4 Ports\u003c\/li\u003e\n\u003cli\u003eM12 Connector, 5 Pins, 4 pcs.):\u003c\/li\u003e\n\u003cli\u003ePort Specification: B (Port Class B)\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-LBB1\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-lxb1_io-link_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-lxb1_tf2z188en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1y087en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE certificate 2\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642585678214,"sku":"EX600-LBB1","price":320.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5059Al_5fafbfa6-1d8e-4e9e-9abf-784085141150.jpg?v=1792335840"},{"product_id":"ex600-spn3","title":"EX600, SI Unit | EX600-SPN3","description":"\u003cp\u003e\u003cstrong\u003eSERIAL INTERFACE UNIT\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\nUp to 9 input \/ output\/ IO-Link units\nUp to 1280 inputs \/ 1280 outputs\nApplicable valve series: JSY, new SY, VQC, S0700, SV\nProtocols: IO-Link, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\nEnclosure: Up to IP67.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtocols: IO-Link, EtherCAT®, EtherNet\/IPTM, DeviceNetTM, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK.\u003c\/li\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC, S0700, SV.\u003c\/li\u003e\n\u003cli\u003eUp to 9 input \/ output\/ IO-Link units.\u003c\/li\u003e\n\u003cli\u003eUp to 1280 inputs \/ 1280 outputs.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-SPN3\u003c\/li\u003e\n\u003cli\u003eItem number: 02186756\u003c\/li\u003e\n\u003cli\u003eType: S (Wired)\u003c\/li\u003e\n\u003cli\u003eSuffix: None\u003c\/li\u003e\n\u003cli\u003eOutput type: 3 [PNP, -COM\u003c\/li\u003e\n\u003cli\u003eEtherNet\/IP™, (2 Ports)]:\u003c\/li\u003e\n\u003cli\u003eProtocol: PN (PROFINET)\u003c\/li\u003e\n\u003cli\u003eLead time: 5 days\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-G_EU.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalogue\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-SPN3\u0026amp;format=STEP-214\" target=\"_blank\" rel=\"noopener\"\u003eCAD model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-smjx_cc-link_en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-secx-ethercat_en-a.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sdnx_devicenet_en-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600-sdnx_devicenet_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn1-2_profinet_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 5\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sen1-2_ethernetip_en-d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 6\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600-sen1-2_ethernetip_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 7\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sprxa-profibus-dp_en-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 8\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600-sprxa-profibus-dp_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 9\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sen3-4_ethernetip-dualport_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 10\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/quick-guide_ex600_sen3-4_ethernetip-dualport_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 11\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn3-4_profinet_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 12\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600_ethernetip_io-link_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperation manual 13\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-smj_tf2z145en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-secx_tf2z166en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sdnxa_tf2z158en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 3\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-spn1-2_tf2z175en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen1-2_tf2z159en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 5\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sprxa_tf2z157en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 6\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-spn3-4_tf2z192en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 7\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen3-4_tf2z179en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 8\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sen3-x80_tf2z189en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual 9\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67642585743750,"sku":"EX600-SPN3","price":755.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/5062l_79cbe53d-c838-4677-882b-e63ac423c967.jpg?v=1792335842"},{"product_id":"ex600-ed2","title":"EX600, Endplate – EX600-ED2","description":"\u003cul\u003e\n\u003cli\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\u003c\/li\u003e\n\u003cli\u003eUp to 9 input \/ output\/ IO-Link units\u003c\/li\u003e\n\u003cli\u003eUp to 1280 inputs \/ 1280 outputs\u003c\/li\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC, S0700, SV\u003c\/li\u003e\n\u003cli\u003eProtocols: IO-Link, EtherNet\/IP\u0026lt;sup\u0026gt;TM\u0026lt;\/sup\u0026gt;, DeviceNet\u0026lt;sup\u0026gt;TM\u0026lt;\/sup\u0026gt;, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\u003c\/li\u003e\n\u003cli\u003eEnclosure: Up to IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eConnector types: M12, 7\/8 inch\u003c\/li\u003e\n\u003cli\u003eIP67 enclosure compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eEnd plate Mounting Position: ED (Mounting Position D Side)\u003c\/li\u003e\n\u003cli\u003eMounting Method: w\/o DIN Rail Mounting Bracket\u003c\/li\u003e\n\u003cli\u003ePower Supply: 2 [M12 (5 Pins) B-coded, IN]\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAdditional information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-ED2\u003c\/li\u003e\n\u003cli\u003eLead time (days): 105\u003c\/li\u003e\n\u003cli\u003eMinimum order quantity: 1\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003cli\u003eTARIC code: 8538909999\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EXW1-EX600-W-E_EU.pdf\"\u003eCatalogue (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-ED2\u0026amp;format=STEP-214\"\u003eCAD model\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn1-2_profinet_en.pdf\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-ed_tf2z193en.pdf\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67762471534982,"sku":"EX600-ED2","price":121.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/FIELDBUS_EX600_END_20PLATE_LARGE_c5c90857-9316-4688-ab0f-f74951a8f7a5.jpg?v=1792673938"},{"product_id":"ex600-ed5","title":"EX600, Endplate – EX600-ED5","description":"\u003cul\u003e\n\u003cli\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\u003c\/li\u003e\n\u003cli\u003eUp to 9 input \/ output\/ IO-Link units\u003c\/li\u003e\n\u003cli\u003eUp to 1280 inputs \/ 1280 outputs\u003c\/li\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC, S0700, SV\u003c\/li\u003e\n\u003cli\u003eProtocols: IO-Link, EtherNet\/IP\u0026lt;sup\u0026gt;TM\u0026lt;\/sup\u0026gt;, DeviceNet\u0026lt;sup\u0026gt;TM\u0026lt;\/sup\u0026gt;, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\u003c\/li\u003e\n\u003cli\u003eEnclosure: Up to IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eConnector types: M12, 7\/8 inch\u003c\/li\u003e\n\u003cli\u003eIP67 enclosure compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eEnd plate Mounting Position: ED (Mounting Position D Side)\u003c\/li\u003e\n\u003cli\u003ePower Supply: 5 [M12 (4\/5 Pins) A-coded, IN\/OUT]\u003c\/li\u003e\n\u003cli\u003eMounting Method: w\/o DIN Rail Mounting Bracket\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAdditional information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-ED5\u003c\/li\u003e\n\u003cli\u003eLead time (days): 3\u003c\/li\u003e\n\u003cli\u003eMinimum order quantity: 1\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003cli\u003eTARIC code: 8538909999\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EXW1-EX600-W-E_EU.pdf\"\u003eCatalogue (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-ED5\u0026amp;format=STEP-214\"\u003eCAD model\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn1-2_profinet_en.pdf\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-ed_tf2z193en.pdf\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67762471633286,"sku":"EX600-ED5","price":142.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/FIELDBUS_EX600_END_20PLATE_LARGE_d94be219-7aa9-46db-9b78-a95fe2fe4419.jpg?v=1792673939"},{"product_id":"ex600-ed4","title":"EX600, Endplate – EX600-ED4","description":"\u003cul\u003e\n\u003cli\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\u003c\/li\u003e\n\u003cli\u003eUp to 9 input \/ output\/ IO-Link units\u003c\/li\u003e\n\u003cli\u003eUp to 1280 inputs \/ 1280 outputs\u003c\/li\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC, S0700, SV\u003c\/li\u003e\n\u003cli\u003eProtocols: IO-Link, EtherNet\/IP\u0026lt;sup\u0026gt;TM\u0026lt;\/sup\u0026gt;, DeviceNet\u0026lt;sup\u0026gt;TM\u0026lt;\/sup\u0026gt;, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\u003c\/li\u003e\n\u003cli\u003eEnclosure: Up to IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eConnector types: M12, 7\/8 inch\u003c\/li\u003e\n\u003cli\u003eIP67 enclosure compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eEnd plate Mounting Position: ED (Mounting Position D Side)\u003c\/li\u003e\n\u003cli\u003eMounting Method: w\/o DIN Rail Mounting Bracket\u003c\/li\u003e\n\u003cli\u003ePower Supply: 4 [M12 (4\/5 Pins) A-coded, IN\/OUT]\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAdditional information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-ED4\u003c\/li\u003e\n\u003cli\u003eLead time (days): 115\u003c\/li\u003e\n\u003cli\u003eMinimum order quantity: 1\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003cli\u003eTARIC code: 8538909999\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EXW1-EX600-W-E_EU.pdf\"\u003eCatalogue (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-ED4\u0026amp;format=STEP-214\"\u003eCAD model\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn1-2_profinet_en.pdf\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-ed_tf2z193en.pdf\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67762471698822,"sku":"EX600-ED4","price":142.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/FIELDBUS_EX600_END_20PLATE_LARGE_f4d1a950-993d-4776-9479-f00d3c86401d.jpg?v=1792673940"},{"product_id":"ex600-ed3","title":"EX600, Endplate – EX600-ED3","description":"\u003cul\u003e\n\u003cli\u003eCentralised multipoint Fieldbus System for digital and analogue I\/O\u003c\/li\u003e\n\u003cli\u003eUp to 9 input \/ output\/ IO-Link master units\u003c\/li\u003e\n\u003cli\u003eUp to 1280 inputs \/ 1280 outputs\u003c\/li\u003e\n\u003cli\u003eApplicable valve series: JSY, new SY, VQC, S0700, SV\u003c\/li\u003e\n\u003cli\u003eProtocols: IO-Link, EtherCAT®, EtherNet\/IP\u0026lt;sup\u0026gt;TM\u0026lt;\/sup\u0026gt;, DeviceNet\u0026lt;sup\u0026gt;TM\u0026lt;\/sup\u0026gt;, CC-Link, PROFINET, PROFIBUS, Modbus\/TCP, POWERLINK\u003c\/li\u003e\n\u003cli\u003eEnclosure: Up to IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eKey features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eConnector types: M12, 7\/8 inch.\u003c\/li\u003e\n\u003cli\u003eEnclosure: IP67.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eSpecifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eEnd plate Mounting Position: ED (Mounting Position D Side)\u003c\/li\u003e\n\u003cli\u003ePower Supply: 3 [7\/8 inch, (5 Pins), IN]\u003c\/li\u003e\n\u003cli\u003eMounting Method: w\/o DIN Rail Mounting Bracket\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAdditional information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePart number: EX600-ED3\u003c\/li\u003e\n\u003cli\u003eLead time (days): 5\u003c\/li\u003e\n\u003cli\u003eMinimum order quantity: 1\u003c\/li\u003e\n\u003cli\u003eCountry of origin: JP\u003c\/li\u003e\n\u003cli\u003eTARIC code: 8538909999\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDocuments\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/content2.smcetech.com\/pdf\/EX600-W-B_EU.pdf\"\u003eCatalogue (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smc.eu\/direct-cad?partNumber=EX600-ED3\u0026amp;format=STEP-214\"\u003eCAD model\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-spn1-2_profinet_en.pdf\"\u003eOperation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-ed_tf2z193en.pdf\"\u003eInstallation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/ce-certificates\/en\/newdoc_ex600_tf1v133en-b.pdf\"\u003eCE certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67762490245510,"sku":"EX600-ED3","price":121.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3811\/0854\/files\/FIELDBUS_EX600_END_20PLATE_LARGE_c8059382-424f-4d7e-bd81-cac553d4a9f2.jpg?v=1792674142"}],"url":"https:\/\/www.tekisindustry.com\/collections\/fieldbus-system-ex600.oembed","provider":"TEKIS Industry Solution – SMC Pneumatic Components","version":"1.0","type":"link"}